Do you have a question? Tel: +0755-89195500
Search
Typical technical performances | Test Items | Test Method | Test Requirements | ||
Tensile strength | ASTM D 2671 | 10MPa minimum | |||
Ultimate elongation | ASTM D 2671 | 200% minimum | |||
Tensile strength after Aging at 150℃ for 168hrs | ASTM D 2671 | 10MPa minimum | |||
Ultimate elongationafter; | ASTM D 2671 | 100% minimum | |||
Heat shock at 200℃ /30min | ASTM D 2671 | No cracking, dropping | |||
Density | ASTM D 792 | 1.2~1.3g/cm3 | |||
Dielectric strength | IEC 60243 | 10kV/mm(2.5mm) min. | |||
Volume resistivity | ASTM D 2671 | 1012Ω cm min. | |||
Low temperature flexibility -40℃ /4hrs | ASTM D 2671 Proc.C | No cracking | |||
Permittivit | ASTM D 150 | 3 (nom.) | |||
Tracking resistanc | ASTM D 2303 | No tracking | |||
ordering information | Color | Standard | Red | ||
Standard packaging | In 1.2-meter [4-foot] lengths | ||||
Ordering description | Specify product name, size and Color (for example, GAT 19/6 Red) | ||||
* Other cutting length are available on request. | |||||
Dimensions | Size(mm) | As supplied(mm) | After recovered (mm) | Standard length (m) | |
D*(Min) | d*(Max) | w*(Min) | |||
Anti-tracking tube (GAT) | |||||
19/6 | 19 | 6 | 2.4 | 30m/spool or 0.5-1.5m | |
30/10 | 30 | 10 | 2.8 | 30m/spool or 0.5-1.5m | |
38/12 | 38 | 12 | 2.8 | 30m/spool or 0.5-1.5m | |
40/16 | 40 | 16 | 2.8 | 30m/spool or 0.5-1.5m | |
49/16 | 49 | 16 | 2.8 | 30m/spool or 0.5-1.5m | |
55/18 | 55 | 18 | 2.8 | 30m/spool or 0.5-1.5m | |
65/21 | 65 | 21 | 3.0 | 30m/spool or 0.5-1.5m | |
75/25 | 75 | 25 | 3.0 | 30m/spool or 0.5-1.5m | |
85/29 | 85 | 29 | 3.3 | 30m/spool or 0.5-1.5m | |
100/40 | 100 | 40 | 3.8 | 0.5-1.5m | |
130/50 | 130 | 50 | 3.8 | 1.0-1.5m | |
Anti-tracking tube with adhesive (GATA) | |||||
30/10 | 30 | 10 | 2.8 | 1.0-1.5 | |
38/12 | 38 | 12 | 2.8 | 1.0-1.5 | |
40/16 | 40 | 16 | 2.8 | 1.0-1.5 | |
49/16 | 49 | 16 | 2.8 | 1.0-1.5 | |
55/18 | 55 | 18 | 2.8 | 1.0-1.5 | |
65/21 | 65 | 21 | 3.0 | 1.0-1.5 | |
75/25 | 75 | 25 | 3.3 | 1.0-1.5 | |
85/29 | 85 | 29 | 3.3 | 1.0-1.5 | |
100/40 | 100 | 40 | 3.8 | 1.0-1.5 | |
130/50 | 130 | 50 | 3.8 | 1.0-1.5 | |
D* = Inner diameter as supplied. d* = Inner diameter after fully recovered. w* = Wall thickness after fully recovered. | |||||