Typical technical performances | Test Items | Test Method | Test Requirements | |
Tensile strength | ASTM D 2671 | 11.7MPa minimum | ||
Ultimate elongation | ASTM D 2671 | 250% minimum | ||
Tensile strength after Aging at 150℃ for 168hrs | UL 224 | 10.3MPa minimum | ||
Ultimate elongation after*Aging at 150℃ for 168hrs | UL 224 | 200% minimum | ||
Heat shock at 200℃ for 4hrs | ASTM D 2671 | No dropping & cracking | ||
Dielectric strength | ASTM D 2671 | 11.9kV/mm minimum | ||
Volume resistance | ASTM D 2671 | 109Ω cm minimum | ||
Cold bend at -30℃ for 1hr | ASTM D 2671 | No cracking | ||
Flammability | ASTM D 2671 Proc. | Self extinguishing in 60sec | ||
Fluid resistance Tensile strength Ultimate elongation | ASTM D 2671, diesel fuel 70℃ /24hrs | 10.4MPa minimum 200% minimum | ||
Dimensions | Size(Inch) | As supplied(mm) | After recovered (mm) | |
D*(Min) | d*(Max) | w*(Min) | ||
1/8 | 3.2 | 1.6 | 0.73 | |
3/16 | 4.8 | 2.4 | 0.80 | |
1/4 | 6.4 | 3.2 | 0.85 | |
3/8 | 9.5 | 4.8 | 0.97 | |
1/2 | 12.7 | 6.4 | 1.16 | |
5/8 | 15.9 | 8.0 | 1.20 | |
3/4 | 19.1 | 9.5 | 1.37 | |
1 | 25.4 | 12.7 | 1.70 | |
1-1/2 | 38.1 | 19.1 | 2.25 | |
2 | 50.8 | 25.4 | 2.40 | |
3 | 76.2 | 38.1 | 2.70 | |
D* = Inner diameter as supplied. d* = Inner diameter after fully recovered. w* = Wall thickness after fully recovered. | ||||
ordering information | Color | Standard | Black | |
Standard packaging | In 1.2-meter [4-foot] lengths or on spools | |||
Ordering description | Specify product name, size and color (for example, GDR 3.2/1.6 Black) | |||
* Other cutting length are available on request. |