Typical technical performances | Test Items | Test Method | Test Requirements | |
Tensile strength | ASTM D 2671 | 18MPa minimum | ||
Ultimate elongation | ASTM D 2671 | 300% minimum | ||
Tensile strength after Aging at 225℃ for 168hrs | UL 224 | 250% minimum | ||
Heat shock at 275℃ for 4hrs | ASTM D 2671 | No cracking | ||
Dielectric strength | ASTM D 2671 | 15.7kV/mm minimum | ||
Volume resistance | ASTM D 2671 | 1014Ω cm minimum | ||
Cold bend at -30℃ for 1hr | ASTM D 2671 | No cracking | ||
Flammability | UL 224 VW-1 | Pass | ||
Dimensions | Size(Inch) | As supplied(mm) | After recovered (mm) | |
D*(Min) | d*(Max) | w*(Min) | ||
3/64 | 1.2 | 0.6 | 0.25 | |
1/16 | 1.6 | 0.8 | 0.25 | |
3/32 | 2.4 | 1.2 | 0.25 | |
1/8 | 3.2 | 1.6 | 0.25 | |
3/16 | 4.8 | 2.4 | 0.25 | |
1/4 | 6.4 | 3.2 | 0.25 | |
3/8 | 9.5 | 4.8 | 0.30 | |
1/2 | 12.7 | 6.4 | 0.30 | |
5/8 | 15.9 | 8.0 | 0.30 | |
3/4 | 19.1 | 9.5 | 0.30 | |
1 | 25.4 | 12.7 | 0.30 | |
1-1/2 | 38.1 | 19.1 | 0.40 | |
2 | 50.8 | 25.4 | 0.50 | |
D* = Inner diameter as supplied. d* = Inner diameter after fully recovered. w* = Wall thickness after fully recovered. | ||||
ordering information | Color | Standard | Black | |
Nonstandard | Clear | |||
Standard packaging | In 1.2-meter [4-foot] lengths or on spools | |||
Ordering description | Specify product name, size and color (for example, GFT-150 1.6/0.8 Clear) | |||
* Other cutting length are available on request. |